SAVE with VIP!Join Now!
FREE Shipping over $699!Learn More
DDS Gadget Logo

Sign In

DALI Biomaintain Collagen Membrane thumbnail
bioMaintain collagen membrane close up thumbnail

Ousia

DALI Biomaintain Sustained Collagen Membrane

SKU: OUSA1S

The classic DALI-Approved Biomaintain Collagen Membrane, which is identical to our former Neomem Membrane, is a sustained function (resorption of 26 - 38 weeks or 6 - 9 months) resorbable bovine collagen membrane.

Identical to the prior Neomem Membrane.

Choose Size

$122.95

$99.99

Buy More, Save More!

Buy 5+ for only $89.99 each!

Save even more with VIP!

Join VIP and save!

Log in to see VIP prices.

  • Sustained function. Resorption Time: 26 - 38 weeks (6 - 9 months).
  • Derived from highly purified type I collagen fibres from bovine Achilles tendon.
  • Compare to: Cytoplast® RTM*, ACE RCM6, Citagenix Neomem
  • Maybe sutured or tacked. Suture pullout strength between 290g and 350g.
  • Cell occlusive - retards epithelium down growth
  • Macromolecular pore size allows nutrient transfer.
  • Exceptional clinical performance and easy in situ placement. Place wet or dry.

Guides and Resources

Questions About DALI Biomaintain Sustained Collagen Membrane

What is the resorption time of this membrane?

As per the product description on this page, the Collagen membrane has a Resorption Time of 26 - 38 weeks (~ 6 - 9 months). The exact language from the IFU is as follows: bioMAINTAIN should be completely resorbed 26 to 38 weeks following surgery. However, probing and subgingival scaling should not be performed prior to six months following surgery to prevent damage to immature tissues. Other assessments of clinical health may be repeated, including plaque, bleeding and tooth mobility indices For more information, you can Download the IFU

Is primary closure necessary? Can the Collagen Membrane be left exposed?

Primary closure is achieved when you are able to bring the tissue together and suture. This and similar bovine collagen membranes are cleared for use with primary closure, and as such should not be left exposed. The exact language from the IFU is as follows: The mucoperiosteal flap is sutured over the collagen membrane and the wound should be closed completely to avoid accelerated resorption due to membrane exposure...Mucoperiosteal incision flaps are developed in the site to be treated. The incision should be sulcular when possible. The clinician should perform thorough debridement and good planing of the defect. As much tissue as possible should be preserved to allow for primary closure of the wound and correct positioning of the flaps. For more information, you can Download the IFU

Does the Membrane require hydration?

This membrane can be placed either dry or hydrated. If the clinician prefers the handling characteristics of the hydrated collagen, the membrane can be hydrated in sterile water or saline solution for approximately five minutes prior to the final placement.

Is this membrane similar to Neomem or Cytoplast® RTM or ACE RCM6?

Yes. All these membranes are completely identical. All bovine collagen membranes that are sold in the US are manufactured by Collagen Matrix, and developed for Longer Resorption for Sustained Site Protection. You can check on the box and it will say manufactured by Collagen Matrix. The only difference between Cytoplast RTM, ACE RCM6, Neomem and Biomaintain is the box/label.

Additional Information for DALI Biomaintain Sustained Collagen Membrane

IFU: For more information, you can Download the IFU

The DALI-Approved Collagen Membrane is a sustained function, resorbable collagen membrane made of Type 1 bovine collagen matrix. It is sold under the Ousia BioMaintain brand and is identical to the previous membrane sold under the Neomem brand. The only difference between these membranes is the box/label.

Our DALI-approved standard, sustained function, resorbable collagen membrane is made of Type 1 bovine collagen matrix and indicated for use in guided tissue procedures to enhance wound healing.

  • Derived from highly purified type I collagen fibres from bovine Achilles tendon.
  • Higher mechanical strength for membrane stabilization in situ using either sutures or resorbable tacks. Suture pullout strength between 290g and 350g
  • Longer in vivo stability and resorption time, 26 to 38 weeks, for sustained function.
  • Optimized flexibility and rigidity for better space maintenance which allows for desired tissue in-growth.
  • Either side of the Neomem can be placed towards the soft tissue or bone.
  • Easily trimmed and placed, wet or dry.
  • Gamma irradiated to sterilise/Nonpyrogenic

bioMAINTAIN Case: Longer Resorption for Sustained Site Protection

bioMaintain case

Ousia bioMaintain has been developed with a proprietary fiber orientation, which allows for optimal space maintenance and mechanical strength. Surgical imagery provided by: Dr. Aron Gonshor, Quebec, Canada

Additional Cases

Case 1: Implant Placement with Simultaneous Guided Bone Regeneration Dr. Steven Faigan, Certified Specialist in Periodontics, Kelowna, British Columbia

  • buccal bone Fig. 1: Resorption of the buccal bone
  • atrophic ridge Fig 2: Grafted atrophic ridge
  • collagen membrane Fig 3: Neomem Resorbable collagen membrane
  • Bone regeneration Fig 4: Regeneration of bone
  • restoration Fig 5: Final restoration

A 63 year old female patient presented requesting implants as a treatment modality to replace several missing posterior teeth in the lower left quadrant. Her natural teeth had been extracted 20 years earlier without replacement, resulting in a significant horizontal ridge deficiency. It was explained to the patient that although implants represented an ideal treatment option, it would be necessary to simultaneously augment the bone to allow for optimum bone integration and stability of the implants. The patient agreed to the proposed surgical and prosthetic treatment plan.

Two threaded, cylindrical, external hex Osseotite® implants (3I, Implant Innovations Inc., Palm Beach Gardens, FL) were placed into the areas of #35 and #37. With optimum implant positioning, and given the horizontal resorption of the host bone in the area, approximately 5-6 threads were exposed on the buccal surface of the implant in site #35 and 3-4 threads on the buccal surface of #37 (fig. 1).

1.0 cc of DynaGraft® II Putty (Citagenix Inc. Montreal, Quebec) was used to augment the deficient ridge and cover the exposed threads of the implants. DynaGraft® II is a bioassayed DFDBA offering the inductive capability required to achieve regeneration of vital bone. DynaGraft® II comes supplied pre-mixed in a reverse phase medium allowing for ease of handling and accurate placement of the material. With simple finger manipulation, the material can be molded into the ideal three dimensional shape to augment the deficient area (Fig. 2). Once in position, the viscosity of DynaGraft® II reduces the risk of dislodgement during final placement, irrigation and flap closure.

A 30x40mm Neomem™ (Citagenix Inc., Montreal, Quebec) GBR resorbable membrane was placed over the graft to assist in bone graft containment and to eliminate connective tissue and epithelial invagination into the surgical site (Fig. 3).

Reapproximation of the flaps was achieved and tension free primary closure established utilizing 5-0 chromic gut sutures. A two stage submerged protocol was undertaken given the simultaneous GBR procedure.

Healing was uneventful and the implants were uncovered at 9 months. Clinical evaluation confirmed the apparent regeneration of bone on the buccal aspect of the mandible with coverage of the exposed implants threads (Fig. 4). At this time, the implants were stable and integrated and 3i’s emergence profile transitional healing abutments were placed. A soft tissue healing period followed for the next 6 weeks. Prefabricated, preparable GingiHue™ Post (3i) prosthetic abutments were inserted and the patient restored with a ceramometal cemented fixed bridge (Fig. 5).

Without the assistance of augmentation materials, endosseous implants would be limited to only those patients that presented with alveolar ridges with adequate bone volume. The predictability of guided bone regeneration techniques has increased the number of implant candidates and has facilitated prosthetically driven restorations.

Case 2: Autogenous Bone Graft Harvesting for Implant Dehiscence Defect Dr. Doug-Seok Sohn, Associate Professor, Chair Department of Oral and Maxillofacial Surgery Daegu Catholic University Hospital, Daegu, South Korea

  • before extractions

Fig. 1: Bridge in place before extractions

  • osteotomy

Fig 2: Osteotomies using MIS drill guide

  • Bone harvest

Fig 3: Autogenous bone harvesting

  • rotografter

Fig. 4: RotoGrafter filled with graft

  • defects around implants

Fig 5: Dehiscence defects around implants

  • Autogenous graft

Fig 6: Autogenous graft in place

  • protect graft

Fig. 7: Neomem Collagen membrane to protect grafted bone

  • primary closure

Fig 8: Tension free primary closure

  • post op

Fig 9: Post-op radiograph

The patient presented with a fourunit bridge that was supported by the second premolar and third molar, which were both unsalvageable (Fig. 1). The bridge was removed, the two teeth were extracted and the site was allowed to heal for six weeks. In this case, no grafting material was used at the time of extraction.

The treatment plan included three endosseous implants to be placed posteriorly to the first premolar to support a fixed prosthesis. At the time of the implant placement surgery, significant horizontal bone loss was observed. Implant sites for three MIS implants were prepared using the MIS drill guide (Fig. 2). Following this and prior to implant placement, an autogenous bone graft was harvested at the implant surgical site using the RotoGrafter™. It was attached to a 16:1 contra-angle handpiece and the drill speed was set to 1000 RPM. The Rotografter was used to perforate the buccal plate inferior as well as distal to the implant sites, thus allowing bone to be collected without compromising implant placement (Fig. 3-5).

Upon insertion of the three root form implants, dehiscence defects were noted ranging from 2mm to 5mm buccally and coronally around the implants. The 100% autogenous bone graft collected from the RotoGrafter was placed in the deficient areas (Fig. 6). A resorbable collagen membrane (Neomem, Citagenix Inc.) was used to cover the graft site and a tension free suture technique was employed to achieve primary closure (Fig. 7-8).

*Cytoplast® is a registered trademark of Osteogenics Biomedical, Inc.

Available Options and SKUs

SKUDescriptionSize
OUSA1SbioMaintain Collagen barrier membrane 15x20, 1 per box15MM X 20MM
OUSA3SbioMaintain Sustained Collagen barrier membrane 30x40, 1 per box30MM X 40MM